High Volume Air Sampling for Viral Aerosols: A Comparative Approach

High Volume Air Sampling for Viral Aerosols: A Comparative Approach

Paperback

Medical ReferenceBiologyGeneral Education

ISBN10: 1249591066
ISBN13: 9781249591061
Publisher: Biblioscholar
Published: Oct 9 2012
Pages: 178
Weight: 0.57
Height: 0.38 Width: 6.14 Depth: 9.21
Language: English

The United States Air Force has high volume biological air sampling equipment available including the XMX/2L-MIL and DFU-1000. Neither system has been evaluated for effectiveness in the collection of viruses. Furthermore, decontamination methods have not been evaluated for these systems after use in sampling for a viral agent. MS2 bacteriophage was used as a surrogate virus. Aerosolized MS2 was released into a 12 m3 exposure chamber. High and moderate airborne concentrations of MS2 were evaluated. Low volume impingers were used for comparative purposes as well. Samples were analyzed using plaque assay and polymerase chain reaction (PCR). At high viral loads the XMX/2L-MIL and DFU-1000 achieved collection effectiveness equal to or greater than the low volume impingers.