• Open Daily: 10am - 10pm
    Alley-side Pickup: 10am - 7pm

    3038 Hennepin Ave Minneapolis, MN
    612-822-4611

Open Daily: 10am - 10pm | Alley-side Pickup: 10am - 7pm
3038 Hennepin Ave Minneapolis, MN
612-822-4611
Exploratory Investigation of Ultrasound Interrogated Passive Sensors based on an Acoustic Metamaterial

Exploratory Investigation of Ultrasound Interrogated Passive Sensors based on an Acoustic Metamaterial

Paperback

Physics

ISBN10: 386628845X
ISBN13: 9783866288454
Publisher: Hartung & Gorre
Published: Oct 1 2025
Pages: 314
Weight: 1.11
Height: 0.66 Width: 6.69 Depth: 9.61
Language: English
Wireless technologies have significantly influenced the development of new sensing concepts for continuous health monitoring and disease detection. Compared to wired solutions, wireless sensors overcome limitations such as risk of infection and discomfort caused by tethered connections. Wireless systems are classified as passive (powerless) and active (powered). Active solutions face significant challenges both in terms of power management and fabrication, requiring the integration of complex electronic components and circuits. Furthermore, active devices may require power source replacement, which can lead to health risks and complications for the patient. In contrast, passive devices present reduced complications thanks to their powerless nature and simpler architecture. Wireless devices typically rely on electromagnetic coupling interrogation for powering or data transmission. Electromagnetic waves, while being a common approach for sensing interrogation, are limited by overheating risks associated with high energy absorption and scattering in tissue. Moreover, the development of customized receivers for these sensing applications requires significant design investment. Due to their mechanical nature, acoustic waves achieve comparable penetration depths to electromagnetic waves at lower power levels. Furthermore, standardized clinical equipment such as echographs can be utilized for interrogation in the MHz regime (ultrasound). Acoustic sensors based on ultrasound interrogation have already been explored, but they are mostly limited by the spatial resolution of commercially-available transducers, often insufficient to measure variations of biomedical parameters of interest (e.g. pressure, temperature). This thesis presents a new approach to perform intracorporeal sensing, investigating the advantages of frequency resolution and ultrasound interrogation. In particular, this is achieved exploiting the high resonant states generated by an acoustic metamaterial. Meta

Also in

Physics