• Open Daily: 10am - 10pm
    Alley-side Pickup: 10am - 7pm

    3038 Hennepin Ave Minneapolis, MN
    612-822-4611

Open Daily: 10am - 10pm | Alley-side Pickup: 10am - 7pm
3038 Hennepin Ave Minneapolis, MN
612-822-4611
Electrical Conductivity Measurements of Lubrication Greases

Electrical Conductivity Measurements of Lubrication Greases

Paperback

Chemistry

ISBN10: 3639357086
ISBN13: 9783639357080
Publisher: Vdm Verlag
Published: May 13 2011
Pages: 72
Weight: 0.26
Height: 0.17 Width: 6.00 Depth: 9.00
Language: English
Methods to reduce electrically induced bearing damage rely on special lubricating greases of either low electric conductivity, to suppress parasitic currents, to prevent the build- up of high electric voltages across the bearing. In either case, it is of interest to know the exact conductivity values of those lubricants. However, no technical standard is available so far on measuring electric conductivity of oil or grease at film thicknesses (1 mm and below). In this work, a measurement cell for simulating the electrical regime of a real bearing conceptually is developed and used with a set of greases. The investigated greases had all quite similar specific resistances, which were all within the variation regime of the total set of greases. The measurements worked satisfactorily for gap widths, i.e. lubricating film thicknesses, of 1 mm and 1/10 mm, respectively. Lubricating films in real bearings typically have a thickness of a few mikrons. Measurements in the test- setup at 1/100 mm gap width showed nonsatisfying results in terms of reproducibility. Some causes are further investigated and possible solutions proposed.

Also in

Chemistry